0026715: Problems in reading STEP short names in complex entities
Add function to find next part of complex entity by name or short name. Add missing short names. Test cases for issue CR26715
This commit is contained in:
@@ -48,7 +48,7 @@ void RWStepBasic_RWConversionBasedUnitAndVolumeUnit::ReadStep(const Handle(StepD
|
||||
Handle(StepBasic_DimensionalExponents) aDimensions;
|
||||
data->ReadEntity(num, 1,"dimensions", ach, STANDARD_TYPE(StepBasic_DimensionalExponents), aDimensions);
|
||||
|
||||
data->NamedForComplex("VOLUME_UNIT",num0,num,ach);
|
||||
data->NamedForComplex("VOLUME_UNIT","VLMUNT",num0,num,ach);
|
||||
if (!data->CheckNbParams(num,0,ach,"volume_unit")) return;
|
||||
|
||||
ent->Init(aDimensions,aName,aConversionFactor);
|
||||
|
||||